|
Vigor 2200We & 2200Wplus Quickjump: Firmware 2.1b Firmware 2.1a |
Vigor 2200(E/X/W) Quickjump: Firmware 2.2 Firmware 2.1a Firmware 2.1 (nicht released) Firmware 2.00a Firmware 2.00 Firmware 1.08 Firmware 1.07d Firmware 1.07c Firmware 1.07 Firmware 1.06c Firmware 1.06b Firmware 1.06a Firmware 1.06 |
Vigor 2000 Quickjump: Firmware 1.08d Firmware 1.08 Firmware 1.07c Firmware 1.07 Firmware 1.06b Firmware 1.06a Firmware 1.06 Firmware 1.05a Firmware 1.04a Firmware 1.04 Firmware 1.03a Firmware 1.03 Firmware 1.02 Firmware 1.01 |
***********************************************************************************************
Release Notes for Vigor2200We & Vigor2200W plus
Firmware Version : v2.1b
Build Date/Time : Fri May 3 20:57:23.24 2002
DrayTek Corp.
Date: 2002/05/03
***********************************************************************************************
V2200WE, V2200WPlus
firmware V2.1b release note
===========================================================
1. Please refers to V2200 V2.1a release
2. Fix intermitent wireless card detection problem when power up
3. Add "Hide SSID" configuration to improve security
>>Wireless LAN setting >> general setting >> Hide SSID
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200We & Vigor2200W plus
Firmware Version : v2.1a
Build Date/Time : SAT Mar 30 08:33 2002
DrayTek Corp.
Date: 2002/04/02
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k2w21a.all --- Released firmware
\Firmware\v2k2w21a.rst --- Released firmware with default
settings
\Firmware\AutoUp\Windows\v2k2w21a.exe --- Auto-Upgrade Utility.
\Firmware\AutoUp\MacOS9\AutoUpgrade_v2.1a --- Auto-Upgrade Utility for Mac OS9
<<< Tools >>>
\Tools\Windows\RtTools_2.01.exe --- Router Tools
\Tools\Windows\VirtualTA\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\Windows\VirtualTA\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\Windows\VirtualTA\VSetup98.exe --- Virtual TA Client 1.06 for Win98
\Tools\MacOS9\Router_Tools --- Router Tools for Mac OS9
Hints for upgrading router's Firmware:
Using Auto-Upgrade Utility:
1. Download the utility v2k2w21a.exe/AutoUpgrade_v2k2w_2.1a to your Windows/Mac PC.
2. Make sure the connectivity between your PC and the router.
3. Double-click the utility, it will find your router and then you should
push "Send" button to upgrade it.
Using Firmware Upgrade Utility:
Firmware Upgrade Utility is a TFTP client software. Before upgrading your router,
its TFTP srever should be enabled in advance and then the utility could send new
firmware file to the router.
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button. Note that now the router is running in
boot loader mode and waiting for upgrade. Now you will see the left-most two LEDs
are blinking togather.
2. Launch the Firmware Upgrade Utility, and select the firmware v2k2w21a.all
to send. After sending, please wait for 30 seconds to finish the upgrade
procedure.
Note: You should restart your web browser after firmware upgrade to get the new
page of web configurator.
Supported Models:
Vigor2200We & Vigor2200W plus
Release Notes: This firmware is the first version for Vigor2200We & Vigor2200W plus.
Please feel free to email us at support@draytek.com.tw and we appreciate for your valuable
feedback and comments on this version.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200 Series
Firmware Version : v2.2
Build Date/Time : Tue Aug 6 14:17:24.64 2002
DrayTek Corp.
Date: 2002/08/06
***********************************************************************************************
Files Description:
<< Firmware >>
\Firmware\v2k20220.all --- Lastest Released firmware
\Firmware\v2k20220.rst --- Lastest Released firmware with
default settings
\Firmware\v2k20220.exe --- Auto-Upgrade Utility for Windows
\Firmware\MacOS9\AutoUpgrade_v2k2_220 --- Auto-Upgrade Utility for Mac OS 9
\Firmware\MacOS10\AutoUpgrade_v2k2_220.dmg --- Auto-Upgrade Utility for Mac OS X
<< Tools >>
\Tools\Windows\RtTools_v2k2_220.exe --- Router Tools for Windows
\Tools\MacOS9\Router_Tools --- Router Tools for Mac OS 9
\Tools\MacOS10\Router_Tools --- Router Tools for Mac OS X
\Tools\SmartVpnDialup_Tools --- PPTP/L2TP Dial-up Tools for
Windows 2000 and XP
<< Document >>
\Doc\User's Guide\ --- Router User's Guide
Hints for upgrading router's Firmware:
Note: Normally the router has been installed the same version of the firmware in the CD before
the shipping.
Using Auto-Upgrade Utility:
1. Download the utility v2k20220.exe/AutoUpgrade_v2k2_220 to your Windows/Mac PC.
2. Make sure the connectivity between your PC and the router.
3. Double-click the utility, it will find your router and then you should
push "Send" button to upgrade it.
Using Firmware Upgrade Utility:
Firmware Upgrade Utility is a TFTP client software. Before upgrading your router,
its TFTP srever should be enabled in advance and then the utility could send new
firmware file to the router.
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button. Note that now the router is running in
boot loader mode and waiting for upgrade. Now you will see the left-most two LEDs
are blinking togather.
2. Launch the Firmware Upgrade Utility, and select the firmware v2k20220.all
to send. After sending, please wait for 30 seconds to finish the upgrade
procedure.
Note: You should restart your web browser after firmware upgrade to get the new
page of web configurator.
Supported Models:
Vigor2200E, Vigor2200, Vigor2200X, Vigor2200W
Release Notes:
[New Functions]:
1. Added SYSLOG information for VPN, WAN log, call log, User access log, DNS request,
TCP/IP connection and online status.
2. Released new Router Tools:
2.1 new version 2.0 of VTA client to add virtual-com port function in Win98/Me.
2.2 new syslog client utility.
3. Added more remote network settings for LAN-to-LAN connectivity.
4. Added a new DDNS provider www.dynamic-nameserver.com.
5. Improved DNS proxy to allow sending an IP address to request the corresponing domain
name.
6. Improved NAT Port Redirection to redirect PPTP connections into local PPTP server.
7. Added the lease time setting on the LAN DHCP server via telnet command
"srv dhcp leasetime xxx".
8. Added VPN connection always-on function.
9. Improved NAT engine to allow fragmented IKE packets pass-through.
[BugFix]:
1. Fixed a PPTP connection problem with Mac OS X.
2. Protected TCP port 1732 and 113 against port scanner from WAN.
3. Fixed a RADIUS problem if remote dial-in users request a call-back option.
4. The SNMP contact information is incorrect( changed to info@draytek.com.tw ).
5. Fixed a FTP Port Redirection problem.
6. Fixed the Telnet's ip ping command can work with directly-connected routing subnets.
7. Fixed a WUI problem that is the field "Peer ISDN Number or Peer VPN server IP" in
the "LAN-to-LAN Dialer Profile Setup > Dial-In Settings" can not be stored the last
digit if the input length is just equal to 15.
8. Fixed a packet trigger problem to allow establishing a LAN-to-LAN connection via
more-route subnets.
9. Fixed a DHCP problem to serve the local subnet configuring with larger or smaller
than CLASS-C.
10. Fixed a PPPoE problem to work with a Dutch cable system.
11. Fixed the VPN's authentication failed problem while establishing a LAN-to-LAN
connection with L2TP over IPSec.
12. Fixed a compatible problem with some ICQ2002a's functions.
13. Fixed a problem that Netmeeting connection can not be always successfully
initialized.
14. Improved re-keying mechanism to work with Netscreen VPN routers.
15. Improved L2TP disconnection phase with Win2000 machines.
16. Improved the internal HTTP and Telnet server to be more stable for administrator
usage.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200 Series
Firmware Version : v2.1a
Build Date/Time : Mon Mar 4 11:54:43.95 2002
DrayTek Corp.
Date: 2002/03/04
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k2021a.all --- Lastest released firmware
\Firmware\v2k2021a.rst --- lastest released firmware with default
settings
\Firmware\AutoUp\Windows\v2k2021a.exe --- Auto-Upgrade Utility, this utility will
work after v1.07 released firmware.
\Firmware\AutoUp\MacOS9\AutoUpgrade_v2.1a.hqx
--- Auto-Upgrade Utility for Mac OS9
<<< Tools >>>
\Tools\Windows\RtTools_2.01.exe --- This Router Tools should work with
v1.07c firmware or laster.
\Tools\Windows\VirtualTA\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\Windows\VirtualTA\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\Windows\VirtualTA\VSetup98.exe --- Virtual TA Client 1.06 for Win98
\Tools\MacOS9\Router_Tools.hqx --- Router Tools for Mac OS9
Hint for upgrading Firmware:
Using Auto-Upgrade Utility:
The Auto-Upgrade Utility can help you to upgrade the router's firmware more easily.
Before downloading the utility, you have to make sure the current running
firmware should be newer than v1.07 (including v1.07).
1. Download the utility v2k2021a.exe to your Windows PC.
2. Make sure the connectivity between your PC and the router.
3. Double-click the utility, it will find your router and then you should
push "Send" button to upgrade it.
Using Firmware Upgrade Utility:
Firmware Upgrade Utility is a TFTP client software. Before upgrading your router,
its TFTP srever should be enabled in advance and then the utility could send new
firmware file to the router.
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button. Note that now the router is running in
boot loader mode and waiting for upgrade. Now you will see the left-most two LEDs
are blinking togather.
2. Launch the Firmware Upgrade Utility, and select the firmware v2k20200.all
to send. After sending, please wait for 30 seconds to finish the upgrade
procedure.
Support Models:
Vigor2200, Vigor2200E, Vigor2200X and Vigor2200W
Note: You should restart your web browser after firmware upgrade to get the new
page of web configurator.
Release Notes:
1. [ICQ2001b]
Fixed the compatible problem between ICQ2001b and ICQ2000b, which somes
functions can not work properly.
2. [VPN]
a. Improved the performance of file transfer.
b. Improved the stabilty of VPN's reconnect while remote site drop suddenly
during connection.
3. [RADIUS Client]
Fixed the problem that RADIUS Clinet can not work with ISDN rmote dial-in.
4. [Web Configurator]
Fixed the problem that in the "> Advanced Setup > VPN and Remote Access
Setup > LAN-to-LAN Dialer Profile Setup > # > 3. Dial-In Setting",
if you use a name of 12 characters or longer, the password will appear after
the first 12 characters of the name.
5. [WAN IP]
Fixed the problem that Vigor router can not access the IP address which has same
subnet ( Class C ) as its WAN IP.
6. [ISDN]
Modified ISDN number input checking. the charater # and * could be typed in
all ISDN dial number input fields on WUI.
7. [DNS]
Fixed the problem that the Secondary IP address of DNS server does not be used
if Primary IP address does not response the DNS request or is wrong address.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200 Series
Firmware Version : v2.1
Build Date/Time : Fri Feb 8 10:31:20.95 2002
DrayTek Corp.
Date: 2002/02/08
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20210.all --- Lastest released firmware
\Firmware\v2k20210.rst --- lastest released firmware with default
settings
\Firmware\AutoUp\Windows\v2k20210.exe --- Auto-Upgrade Utility, this utility will
work after v1.07 released firmware.
\Firmware\AutoUp\MacOS9\AutoUpgrade_v2.1.hqx
--- Auto-Upgrade Utility for Mac OS9
<<< Tools >>>
\Tools\Windows\RtTools_2.01.exe --- This Router Tools should work with
v1.07c firmware or laster.
\Tools\Windows\VirtualTA\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\Windows\VirtualTA\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\Windows\VirtualTA\VSetup98.exe --- Virtual TA Client 1.06 for Win98
\Tools\MacOS9\Router_Tools.hqx --- Router Tools for Mac OS9
Hint for upgrading Firmware:
Using Auto-Upgrade Utility:
The Auto-Upgrade Utility can help you to upgrade the router's firmware more easily.
Before downloading the utility, you have to make sure the current running
firmware should be newer than v1.07 (including v1.07).
1. Download the utility v2k20210.exe to your Windows PC.
2. Make sure the connectivity between your PC and the router.
3. Double-click the utility, it will find your router and then you should
push "Send" button to upgrade it.
Using Firmware Upgrade Utility:
Firmware Upgrade Utility is a TFTP client software. Before upgrading your router,
its TFTP srever should be enabled in advance and then the utility could send new
firmware file to the router.
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button. Note that now the router is running
in boot loader mode and waiting for upgrade. Now you will see the left-most two
LEDs are blinking togather.
2. Launch the Firmware Upgrade Utility, and select the firmware v2k20200.all
to send. After sending, please wait for 30 seconds to finish the upgrade
procedure.
Support Models:
Vigor2200, Vigor2200E, Vigor2200X and Vigor2200W
Note: You should restart your web browser after firmware upgrade to get the new
page of web configurator.
Release Notes:
1. [Multi-NAT]
a. Added Muiti-NAT function. You can set multiple Wan IPs in web configurator.
Please click the "WAN IP Alias" button (is available while "Broadband Access"
enable) in
" > Quick Setup > Internet Access Setup > Static or dynamic IP".
b. DMZ host can be set for each Wan IP in " > Advanced Setup > NAT Setup
> DMA Host Setup" of web configurator.
2. [MSN Messenger]
Support MSN Messenger v4.6 ( v3.6 also can work properly )
3. [ICQ2001b]
Spport ICQ2001b ( ICQ2000b also can work properly ), but there is a compatible
problem between ICQ2001b and ICQ2000b, some functions do not work properly.
This will be fixed in the next version.
4. [VPN]
a. Added VPN disable function ( include L2TP, PPTP, IPSec Tunnel ). you can use
the function to run a VPN server inside your LAN and pass through the NAT.
setting is " > Advanced Setup > VPN and Remote Access Setup
> Remote Access Control Setup"
b. Added PFS ( Perfect Forward Secrecy ) automatic detection, which fixed the
problem that can not establish a VPN connection with Linux server.
5. [RADIUS]
Added RADIUS client function. The function can work with PPTP, L2TP remote dial
in, but ISDN remote dial-in still have problem. ( will be fixed in the next
version ). Setting is in " > Advanced Setup > RADIUS Setup" of web
configurator.
6. [DDNS]
a. Supported DDNS service providers including dyndns.org (www.dyndns.org),
NO-IP.COM Free (www.no-ip.com), DtDNS (www.dtdns.com) and ChangeIP.com
(www.changeip.com).
b. Improved WAN IP update procedures to prevent abusive updates.
c. Added a new domain name "dyndns.biz" for complying with dyndns.org.
7. [Web Configurator]
a. Improved HTTP daemon to speed the file searching.
b. Moved "Syslog Setup" from " > System Management > Diagnostic Tools" to
"> System Management"
c. Added "RADIUS Setup" in " > Advanced Setup"
d. Added "VPN and Remote Access Setup" in "Advanced Setup"
e. Added "Remote Access Control Setup" in " > Advanced Setup > VPN and
Remote Access Setup" The setting can enable/disable L2TP VPN, PPTP VPN,
IPsec VPN and ISDN Remote Dial-In services.
f. Removed "Remote Dial-In Access Setup" in " > Quick Setup", the setting is
replaced by new page " > Advanced Setup > VPN and Remote Access Setup
> PPP General Setup".
g. Moved "IKE/IPSec Setup" from " > Advanced Setup" to " > Advanced Setup
> VPN and Remote Access Setup" and changed to "VPN IKE/IPSec Setup"
h. Moved "Remote Dial-In User Setup" from " > Advanced Setup" to
" > Advanced Setup > VPN and Remote Access Setup"
i. Moved "LAN-to-LAN Dialer Profile Setup" from " > Advanced Setup" to
" > Advanced Setup > VPN and Remote Access Setup"
j. Added new function "Configuration Backup/Restoration" in " > System Management"
to backup/restore configuration profile.
8. [NAT]
a. Portmap checking improvement. Fixed the problem that sometimes router becomes
very slow after establishing a lot of sessions.
b. Fixed the problem that port 56415 could be found from Wan port.
c. Fixed the problem that FXP ( a FTP application ) can not work properly.
9. [Idle Time-out]
Fixed the problem that idle time-out function does not work properly with VPN
or ISDN connection.
10. [Telnet]
Fixed the crash problem that diaplaying the "Online status" page with a 10 second
refresh rate and running "ip ping xx.xx.xx.xx" in Telnet connection produce the
router to reboot.
11. [PPP]
Fixed the follwoing problems to improve the PPP's stability:
a. ISDN PPP Connetion failed problem with some ISPs which may change the
authendicating protocol from PAP to CHAP during negotiating statge.
b. sometimes connetion can not be dropped when remote site does not response
the Echo_Request packet for a while.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200 Series
Firmware Version : v2.00a
Build Date/Time : Tue Dec 11 15:50:44.62 2001
DrayTek Corp.
Date: 2001/12/12
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20200.all --- Lastest released firmware
\Firmware\v2k20200.rst --- lastest released firmware with default
settings
\Firmware\AutoUp\Windows\v2k20200a.exe --- Auto-Upgrade Utility, this utility will
work after v1.07 released firmware.
\Firmware\AutoUp\MacOS9\AutoUpgrade_v2.00a.hqx
--- Auto-Upgrade Utility for Mac OS9
<<< Tools >>>
\Tools\Windows\RtTools_2.01.exe --- This Router Tools should work with
v1.07c firmware or laster.
\Tools\Windows\VirtualTA\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\Windows\VirtualTA\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\Windows\VirtualTA\VSetup98.exe --- Virtual TA Client 1.06 for Win98
\Tools\MacOS9\Router_Tools.hqx --- Router Tools for Mac OS9
Hint for upgrading Firmware:
Using Auto-Upgrade Utility:
The Auto-Upgrade Utility can help you to upgrade the router's firmware more easily.
Before downloading the utility, you have to make sure the current running
firmware should be newer than v1.07 (including v1.07).
1. Download the utility v2k20200a.exe to your Windows PC.
2. Make sure the connectivity between your PC and the router.
3. Double-click the utility, it will find your router and then you should
push "Send" button to upgrade it.
Using Firmware Upgrade Utility:
Firmware Upgrade Utility is a TFTP client software. Before upgrading your router,
its TFTP srever should be enabled in advance and then the utility could send new
firmware file to the router.
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button. Note that now the router is running in
boot loader mode and waiting for upgrade. Now you will see the left-most two LEDs
are blinking togather.
2. Launch the Firmware Upgrade Utility, and select the firmware v2k20200.all
to send. After sending, please wait for 30 seconds to finish the upgrade
procedure.
Support Models:
Vigor2200, Vigor2200E, Vigor2200X and Vigor2200W
Release Notes:
1. [ISDN BOD]
fixed the malfunction problem.
2. [VPN]
fixed the problem that the on-line status display is not correct.
3. [PPTP]
fixed PPTP server pass-through problem
4. [Syslog]
a. Web Configurator: add a "Syslog Setting" in "Diagnostic Tools" for
Syslog setting. Please click "Enable" and enter the host's IP in
"Syslog output IP" to enable the function.
b. Currrently, ISDN call information may send syslog's message to host.
Other message will be added in the next version.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200 Series
Firmware Version : v2.00
Build Date/Time : Tru Nov 15 18:4:1.28 2001
DrayTek Corp.
Date: 2001/11/16
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20200.all --- Lastest released firmware
\Firmware\v2k20200.rst --- lastest released firmware with default
settings
\Firmware\AutoUp\Windows\v2k20200.exe --- Auto-Upgrade Utility, this utility will
work after v1.07 released firmware.
\Firmware\AutoUp\MacOS9\AutoUpgrade_v2.00.hqx
--- Auto-Upgrade Utility for Mac OS9
<<< Tools >>>
\Tools\Windows\RtTools_2.01.exe --- This Router Tools should work with
v1.07c firmware or laster.
\Tools\Windows\VirtualTA\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\Windows\VirtualTA\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\Windows\VirtualTA\VSetup98.exe --- Virtual TA Client 1.06 for Win98
\Tools\MacOS9\Router_Tools.hqx --- Router Tools for Mac OS9
Hint for upgrading Firmware:
Using Auto-Upgrade Utility:
The Auto-Upgrade Utility can help you to upgrade the router's firmware more easily.
Before downloading the utility, you have to make sure the current running
firmware should be newer than v1.07 (including v1.07).
1. Download the utility v2k20200.exe to your Windows PC.
2. Make sure the connectivity between your PC and the router.
3. Double-click the utility, it will find your router and then you should
push "Send" button to upgrade it.
Using Firmware Upgrade Utility:
Firmware Upgrade Utility is a TFTP client software. Before upgrading your router,
its TFTP srever should be enabled in advance and then the utility could send new
firmware file to the router.
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button. Note that now the router is running in
boot loader mode and waiting for upgrade. Now you will see the left-most two LEDs
are blinking togather.
2. Launch the Firmware Upgrade Utility, and select the firmware v2k20200.all
to send. After sending, please wait for 30 seconds to finish the upgrade
procedure.
Support Models:
Vigor2200, Vigor2200E, Vigor2200X and Vigor2200W
Release Notes:
1. Support VPN/IPSec function. please refer to the files:
"VPN_chapter.pdf" for user manual.
"VpnReadme.txt" for some application hints.
2. Improve NAT to support some specific applications: ICQ2000, MSN Messenger,
NetMeeting. Don't need to set DMZ host any more and can support multi-users in the
local LAN.
3. Network Neighborhood in PC ( Third-party application in Mac ) can work pass-thru
NAT while a host dial-in via ISDN or VPN.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200 Series
Firmware Version : v1.08
Build Date/Time : Fri Oct 19 15:41:38.66 2001
DrayTek Corp.
Date: 2001/10/25
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20108.all --- Lastest released firmware
\Firmware\v2k20108.rst --- lastest released firmware with default
settings
\Firmware\AutoUp\Windows\v2k20108.exe --- Auto-Upgrade Utility, this utility will
work after v1.07 released firmware.
\Firmware\AutoUp\MacOS9\AutoUpgrade_v1.08.hqx
--- Auto-Upgrade Utility for Mac OS9
<<< Tools >>>
\Tools\Windows\RtTools_2.01.exe --- This Router Tools should work with
v1.07c firmware or laster.
\Tools\Windows\VirtualTA\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\Windows\VirtualTA\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\Windows\VirtualTA\VSetup98.exe --- Virtual TA Client 1.06 for Win98
\Tools\MacOS9\Router_Tools.hqx --- Router Tools for Mac OS9
Hint for upgrading Firmware:
Using Auto-Upgrade Utility:
The Auto-Upgrade Utility can help you to upgrade the router's firmware more easily.
Before downloading the utility, you have to make sure the current running
firmware should be newer than v1.07 (including v1.07).
1. Download the utility v2k2_108.exe to your Windows PC.
2. Make sure the connectivity between your PC and the router.
3. Double-click the utility, it will find your router and then you should
push "Send" button to upgrade it.
Using Firmware Upgrade Utility:
Firmware Upgrade Utility is a TFTP client software. Before upgrading your router,
its TFTP srever should be enabled in advance and then the utility could send new
firmware file to the router.
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button. Note that now the router is running in
boot loader mode and waiting for upgrade. Now you will see the left-most two LEDs
are blinking togather.
2. Launch the Firmware Upgrade Utility, and select the firmware v2k20108.all
to send. After sending, please wait for 30 seconds to finish the upgrade
procedure.
Support Models:
Vigor2200, Vigor2200E, Vigor2200X and Vigor2200W
Release Notes:
1. [Web Configurator]
a. Added "Clear" and "Clear All" buttons for DDNS, Open Ports and
Call Schedule Profiles.
b. Improved HTTP daemon against attacks by nimda virus.
c. Removed "None" option of "Link Type" for "Dialing to a Single ISP" and
"Call Control and PPP/MP Setup".
d. Improved all password fields could be use '*' and '+' characters.
2. [PPPoE]
Added the DSS over PPPoE function for PPPoE-enabled ADSL access.
Note: DSS stands for Dynamic Service Selection. If the PPPoE-enabled
ADSL access netowrk supports multiple PPPoE servers for differnet service
grade, the function can automatically connect your router to correct
PPPoE server.
3. [NAT]
Fixed a Port Redirection problem.
4. [ISDN dial-backup]
Improved the stability of ISDN dial-backup function.
5. [DDNS]
Improved DDNS function. If you have any DDNS update problems, you can use
telnet command "ddns log" to get logs and send back to support center.
6. [Cable Access]
Add a "PING to keep alive" function for Cable access users.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200 Series
Firmware Version : v1.07d
Build Date/Time : Wed Sep 19 19:49:40.73 2001
DrayTek Corp.
Date: 2001/09/19
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20107.all --- Lastest released firmware
\Firmware\v2k20107.rst --- lastest released firmware with default
settings
\Firmware\v2k2_107d.exe --- Auto-Upgrade Utility, this utility will work
after v1.07 released firmware.
This is a patch of v1.07c version. All tools could use v1.07c release level.
Hint for upgrading Firmware:
Using Auto-Upgrade Utility:
The Auto-Upgrade Utility can help you to upgrade the router's firmware more easily.
Before downloading the utility, you have to make sure the current running
firmware should be newer than v1.07 (including v1.07).
1. Download the utility v2k2_107d.exe to your Windows PC.
2. Make sure the connectivity between your PC and the router.
3. Double-click the utility, it will find your router and then you should
push "Send" button to upgrade it.
Using Firmware Upgrade Utility:
Firmware Upgrade Utility is a TFTP client software. Before upgrading your router,
its TFTP srever should be enabled in advance and then the utility could send new
firmware file to the router.
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button. Note that now the router is running in
boot loader mode and waiting for upgrade. Now you will see the left-most two LEDs
are blinking togather.
2. Launch the Firmware Upgrade Utility, and select the firmware v2k20107.all
to send. After sending, please wait for 30 seconds to finish the upgrade
procedure.
Support Models:
Vigor2200, Vigor2200E, Vigor2200X and Vigor2200W
Release Notes:
1. [Web Configurator]
a. Remove "None" option of "Link Type" for "Dialing to a Single ISP" and
"Call Control and PPP/MP Setup".
b. Add more heximal records for "Diagnostic Tools" < "Triggered Dial-Out
Packet Header".
c. Fix a bug that all password fields can not use '*' character.
2. [PPPoE for WAN port]
Add a feature such that users can use "ISP Name" to specify the
PPPoE-based ADSL provider. For example, when you have two or more
PPPoE server on the same ADSL line, such as adsl-isp1, adsl-isp2
and adsl-ips3. If the adsl-isp1 offers PPPoE access service for
you. You have to type "adsl-isp1" in the "ISP Name" field to
specify the PPPoE server. You could click "Internet Access Setup" <
"PPPoE" to find the "ISP Name" field.
3. [PPTP for WAN port]
Fixed a NAT portmap problem using PPTP tunnel mode with ADSL modem.
4. [DNS Proxy and Wireless LAN]
Fixed a DNS bug for wireless LAN hosts.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200 Series
Firmware Version : v1.07c
Build Date/Time : Thu Sep 6 16:10:44.53 2001
DrayTek Corp.
Date: 2001/09/06
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20107.all --- Lastest released firmware
\Firmware\v2k20107.rst --- lastest released firmware with default
settings
\Firmware\v2k2_107c.exe --- Auto-Upgrade Utility, this utility will work
after v1.07 released firmware.
<<< Tools >>>
\Tools\RtTools_2.01.exe --- This Router Tools should work with v1.07 firmware.
\Tools\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\VSetup98.exe --- Virtual TA Client 1.06 for Win98
Hint for upgrading Firmware:
Using Auto-Upgrade Utility:
The Auto-Upgrade Utility can help you to upgrade the router's firmware more easily.
Before downloading the utility, you have to make sure the current running
firmware should be newer than v1.07 (including v1.07).
1. Download the utility v2k2_107c.exe to your Windows PC.
2. Make sure the connectivity between your PC and the router.
3. Double-click the utility, it will find your router and then you should
push "Send" button to upgrade it.
Using Firmware Upgrade Utility:
Firmware Upgrade Utility is a TFTP client software. Before upgrading your router,
its TFTP srever should be enabled in advance and then the utility could send new
firmware file to the router.
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button. Note that now the router is running in
boot loader mode and waiting for upgrade. Now you will see the left-most two LEDs
are blinking togather.
2. Launch the Firmware Upgrade Utility, and select the firmware v2k20107.all
to send. After sending, please wait for 30 seconds to finish the upgrade
procedure.
Support Models:
Vigor2200, Vigor2200E, Vigor2200X and Vigor2200W
Release Notes:
1. [Router Tools and Virtual TA Client]
After v1.07 firmware, you should use new Router Tools 2.01 version.
2. [Virtual TA]
Fixed Virtual TA can't work on v1.07.
3. [PPP-over-V.110]
Add PPPoV110 indication on the "Online Status" page.
4. [Always-On for PPPoE/PPTP]
Add an "Always-On" setting for PPPoE/PPTP dial-up connection.
5. [Disable PING from the Internet]
Add a checkbox under Management Setup to enable/disable PING packets from the
Internet.
6. [Call Scheduler]
Change the default settings of schedules to be 2000/01/01.
7. [RIP control for LAN]
Add a RIP control for LAN interface under "LAN TCP/IP and DHCP Setup" page. If
your local networks has many subnets want to share the router to the Internet.
Please set "RIP Protocol Control" to be "1st subnet".
8. [Static or Dynamic IP for WAN port]
Improve Dynamic IP to be compatible with some cable providers.
9. [PPTP for WAN port]
If users select PPTP for WAN port, the PPTP server will be 10.0.0.138 and the
IP address of WAN port will be 10.0.0.150 with netmask 255.0.0.0.
10. [LAN-to-WAN Throughput]
Improve the throughput between LAN and WAN interface.
11. [Wireless LAN]
Improve web configuration for the part of wireless LAN settings.
12. [DNS Proxy]
Improve DNS Proxy for working with RedHat 7.1 Linux.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200 Series
Firmware Version : v1.07
Build Date/Time : Tue Jun 26 11:54:2.26 2001
DrayTek Corp.
Date: 2001/06/22
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20107.all --- Lastest released firmware
\Firmware\v2k20107.rst --- lastest released firmware with default
settings
\Firmware\v2k2_107.exe --- Auto-Upgrade Utility, this utility will work
after v1.07 firmware.
<<< Tools >>>
\Tools\RtTools_2.01.exe --- This Router Tools should work with v1.07 firmware.
\Tools\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\VSetup98.exe --- Virtual TA Client 1.06 for Win98
Hint for upgrading Firmware:
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button.
2. Launch the Firmware Upgrade Utility to select the firmware to send. The utility
in the Router Tools.
Release Notes:
1. [Router Tools and Virtual TA Client]
The Router Tools and Virtual TA Client have been updated, you have to uninstall
them from your computer first, then install new ones. You will get new release
in the Tools folder.
a. The system administrator password has been encrypted between router
and Smart Start Wizard.
b. Fixed a dual-CPUs problem for Virtual TA Clients.
2. [ISDN interface control]
Add a ISDN interface control option on Web Configurator to enable or disable
ISDN port. You will find the option in "ISDN Setup" of Basic Setup group.
3. [PPP-over-V.110]
Support PPP over V.110 protocol for GSM mobile users remote dial-in access.
4. [MTU setting for WAN]
Add a Telnet command "wan mtu ..." to set the MTU (Maximum Transmission Unit)
for the Ethernet WAN interface. You can use this command to configure the
MTU size for ISDN, PPPoE, PPTP and Static IP modes.
5. [SNMP Agent]
Support SNMP (Simple Network Management Protocol) for improving the capabilities
of network management. You will find SNMP Setup in the "Management Setup" of
System Management group.
6. [DDNS function]
Support DDNS (Dynamic Domain Name System) function. If you are a registered
user of www.dyndns.org (the provider of DDNS), you can give one or many domain
names for your active WAN interface using the function.
7. [Time Client and Call Scheduler]
Support NTP (Network Time Procotol) client and Call Scheduler function. The
Call Scheduler funtion provides you to schedule router's WAN connection or
LAN-to-LAN connection by your local time. The NTP client setup could be
found in "Time Setup" of System Management group. The profiles of Call Scheduler
could be found in "Call Scheduler Setup" of Advanced Setup group. Also you will
see these profiles could be assigned for Interface Access (ISDN, PPPoE and PPTP)
and LAN-to-LAN access.
8. [Online Status]
Add a System Uptime on the "Online Status" page of web configurator.
9. [DHCP Server]
If put zero in the IP Pool Counts, the dynamic IP pool will be disabled. Now you
can use Telnet command set "srv dhcp fixip" to add or delete static IP pool. This
static IP pool supports 10 IP addresses.
> srv dhcp fixip ?
% Valid subcommands are:
add clr del
Under the "srv dhcp fixip" command string, it support three subcommands: "add",
"clr" and "del".
> srv dhcp fixip add ?
% srv dhcp fixip add <IP Addr> <MAC Addr XX-XX-XX-XX-XX-XX> <Host ID>
The "add" subcommand can add a specific IP address based on host's Ethernet MAC
address. The Host ID is optional. For example, if you want to specify a IP address
192.168.1.123 to a specific computer with MAC address 00-50-7F-12-34-56, you can
try the following command to add.
> srv dhcp fixip add 192.168.1.123 00-50-7F-12-34-56 vigor
> srv dhcp fixip del ?
% srv dhcp fixip del <IP Addr>
The "del" subcommand can delete a pre-assigned IP address from the static IP pool.
For example,
> srv dhcp fixip del 192.168.1.123
the host 192.168.1.123 will be removed from the static IP pool.
> srv dhcp fixip clr
The "clr" subcommand can clear the static IP pool to default values.
10. [Verify default Settings]
A new Telnet command "sys cfg status" can check if the router is working with
default settings. If yes, you will see the following message.
> sys cfg status
Profile version: 0x2 Status: 0 (0x293ab002)
where Status: 0 (0x293ab002) means the router is default settings.
11. [Auto Firmware Upgrade]
After v1.07 version, Vigor2200 will support Auto Firmware Upgrade Utility to
update vigor's firmware automatically. Now, the utility just can run on the
Windows machines.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2200 Series
Firmware Version : v1.06c
Build Date/Time : Wed Mar 28 16:36:42.5 2001
DrayTek Corp.
Date: 2001/03/28
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20106.all --- Lastest released firmware
\Firmware\v2k20106.rst --- lastest released firmware with default
settings
Hint for upgrading Firmware:
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button.
2. Launch the Firmware Upgrade Utility to select the firmware to send.
Release Notes:
1. Support 3V and 5V Flash EPROM.
2. Fix a WAN port buffer leakage problem.
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2200 Series
Firmware Version : v1.06b
Build Date/Time : Thu Feb 15 15:17:51.43 2001
DrayTek Corp.
Date: 2001/02/16
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20106.all --- Lastest released firmware
\Firmware\v2k20106.rst --- lastest released firmware with default
settings
Hint for upgrading Firmware:
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button.
2. Launch the Firmware Upgrade Utility to select the firmware to send.
Release Notes:
1. Modify the Ethernet driver to improve router's QoS for internal users to surf
the Internet.
2. Fixed a Typing error in ipnatdmz.sht of Web Configurator.
"Corbg." ---> "Corp."
3. ISDN dial-in improvement. Sometimes the dial-in will be failed when
the remote ISDN TA or router to use ML-PPP to dial into Vigor2200 or Vigor2200X.
4. Fix a problem that Open Ports can not input 65535 port number.
5. Fix a Clear button problem under "Advanced Setup" > "IP Filter/Firewall Setup"
> "Edit Filter Set".
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2200 Series
Firmware Version : v1.06a
Build Date/Time : Thu Jan 11 16:42:46.42 2001
DrayTek Corp.
Date: 2001/01/12
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20106.all --- Lastest released firmware
\Firmware\v2k20106.rst --- lastest released firmware with default
settings
<<< Router Tools & Virtual TA Client >>>
\Tools\Windows\RtSetup.exe --- Router Tools for all Windwos Platforms
\Tools\Windows\VSetup2k.exe --- VTA client for Windows 2000
\Tools\Windows\VSetup95.exe --- VTA client for Windows 95
\Tools\Windows\VSetup98.exe --- VTA client for Windows 98
\Tools\Mac OS\RtTool.hqx --- Router Tools for Mac OS
<<< User Manual >>>
\Manual\v2k2man.pdf --- Vigor2200's User Manual
Hint for upgrading Firmware:
1. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button.
2. Launch the Firmware Upgrade Utility to select the firmware to send.
Release Notes:
1. Improve DMZ host function for Mac OS 9.
2. Add Open Ports function which allow users to open a port range
for specific network applications.
3. Improve NAT engine for FTP protocol pass-thru.
4. Fix a LAN-to-LAN and ISP access via ISDN simultaneouly problem which
when a LAN-to-LAN connection is up the ISP access will be failed.
5. Improve Web Configurator for more user-friendly with JavaScripts.
6. Improve Web Configurator for IE 5.5 and Netscape 6.0 browser.
7. IPSec ESP tunnel mode pass-thru support.
8. All Vigor2200 series routers (Vigor2200, Vigor2200E and Vigor2200X)
use the same firmware.
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2200 Series
Firmware Version : v1.06
Build Date/Time : Fri Nov 17 12:16:59.14 2000
DrayTek Corp.
Date: 2000/11/17
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k20106.all --- Lastest released firmware
<<< Router Tools & Virtual TA Client >>>
\Tools\Windows\RtSetup.exe --- Router Tools for all Windwos Platforms
\Tools\Windows\VSetup2k.exe --- VTA client for Windows 2000
\Tools\Windows\VSetup95.exe --- VTA client for Windows 95
\Tools\Windows\VSetup98.exe --- VTA client for Windows 98
\Tools\Mac OS\RtTool.hqx --- Router Tools for Mac OS
Hint for upgrading Firmware:
1. Uncompress the file v2k20106.zip to be upgradeable firmware v2k20106.all.
2. Using Web Configurator to enable TFTP server. Please click "System Management"
> "Firmware Upgrade" to press OK button.
3. Launch the Firmware Upgrade Utility to select the firmware to send.
Release Notes:
1. Most of features are ready as Vigor2000's v1.06 version. Please refer to
the release note of Vigor2000's v1.06.
2. DMZ Host support.
The DMZ (De-militized host) can expose a internal host to be public. For
some special application, such as Microsoft Game --- Age of Empires. You
should set the game host to be the DMZ host to play the game with other
Internet users.
3. For specific applications configurations are below.
Netmeeting:
Set the Netmeeting host to be the DMZ host.
mIRC:
Set the mIRC host to be the DMZ host.
ICQ:
Set the ICQ host to be the DMZ host.
PPTP Pass-Thru:
No other setting needed.
Battlenet:
1. Warcraft:
Create a redirected port UDP:6112 for the game host.
2. Starcraft:
Create a redirected port UDP:6112 for the game host.
3. Diablo, Dialbo II:
Create a redirected port UDP:4000 for the game host.
Quake:
Create a redirected port UDP:27960 for the game host.
Tribes:
Set the Tribes host to be the DMZ host.
Napter:
Create a redirected port TCP:6699 for the MP3 sharing host.
GunTella:
Create a redirected port TCP:6346 for the MP3 sharing host. Note that
if you want to share internal media files to outside, you should click
"Config" on the application menu to update the Local IP to be the WAN
IP of the Internet connection.
4. Telnet commands for DHCP client troubeshooting.
> ip dhcpc status --- View the DHCP client status on WAN interface.
> ip dhcpc release --- Release all settings of WAN interface.
> ip dhcpc renew --- Renew all settings of WAN interface.
> log -i -t --- Display all DHCP messages between Vigor2200 and
Cable head end system.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2000
Firmware Version : v1.08d
Build Date/Time : Wed Dec 5 12:56:53.1 2001
DrayTek Corp.
Date: 2001/12/05
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k00108.all --- Lastest released firmware
(v2k00108.bin + v2k00108.web)
\Firmware\v2k00108.rst --- Lastest released firmware
(v2k00108.cfg + v2k00108.bin + v2k00108.web)
\Firmware\v2k00108.bin --- Lastest released firmware
(router program firmware only)
\Firmware\v2k00108.cfg --- The ROM file of factory default settings
excluding Lan2Lan and IP Filter
\Firmware\v2k00108.web --- The ROM file of webpages of Web Configurator
<<< Tools >>>
\Tools\RtTools_2.01.exe --- This Router Tools should work with v1.07c
firmware or laster.
\Tools\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\VSetup98.exe --- Virtual TA Client 1.06 for Win98
Hint for upgrading Firmware:
1. The file v2k00108.all should be upgraded under the boot loader mode.
Please use console port (RS-232 with 115200 8n1) to force the router enter
boot loader mode.
2. If you don't care the current settings in your Vigor2000 or you want to
reset the router, you could upgrade v2k00108.rst to resotore settings
to be default values. We recommended you upgrade this file, if your
router firmware version is older than v1.03.
3. If you can't connect to console port to force router enter boot loader mode
to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator
to upgrade *.bin first and then *.web. Note that you have to wait for 10
seconds between two upgrading procedures. Finishing all upgrade, please power
off-on again.
Support Models:
Vigor2000
Release Notes:
1. [Web Configurator]
a. Fixed IE6.0 layout problem.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2000
Firmware Version : v1.08
Build Date/Time : Fri Oct 19 16:0:13.54 2001
DrayTek Corp.
Date: 2001/10/25
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k00108.all --- Lastest released firmware
(v2k00108.bin + v2k00108.web)
\Firmware\v2k00108.rst --- Lastest released firmware
(v2k00108.cfg + v2k00108.bin + v2k00108.web)
\Firmware\v2k00108.bin --- Lastest released firmware
(router program firmware only)
\Firmware\v2k00108.web --- The ROM file of webpages of Web Configurator
<< Tools >>>
\Tools\Windows\RtTools_2.01.exe --- This Router Tools should work with
v1.07c firmware or laster.
\Tools\Windows\VirtualTA\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\Windows\VirtualTA\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\Windows\VirtualTA\VSetup98.exe --- Virtual TA Client 1.06 for Win98
\Tools\MacOS9\Router_Tools --- Router Tools for Mac OS9
Hint for upgrading Firmware:
1. The file v2k00108.all should be upgraded under the boot loader mode.
Please use console port (RS-232 with 115200 8n1) to force the router enter
boot loader mode.
2. If you don't care the current settings in your Vigor2000 or you want to
reset the router, you could upgrade v2k00108.rst to resotore settings
to be default values. We recommended you upgrade this file, if your
router firmware version is older than v1.03.
3. If you can't connect to console port to force router enter boot loader mode
to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator
to upgrade *.bin first and then *.web. Note that you have to wait for 10
seconds between two upgrading procedures. Finishing all upgrade, please power
off-on again.
Support Models:
Vigor2000
Release Notes:
1. [Web Configurator]
a. Added "Clear" and "Clear All" buttons for DDNS, Open Ports and
Call Schedule Profiles.
b. Improved HTTP daemon against attacks by nimda virus.
c. Removed "None" option of "Link Type" for "Dialing to a Single ISP" and
"Call Control and PPP/MP Setup".
d. Added more heximal records for "Diagnostic Tools" > "Triggered Dial-Out
Packet Header".
e. Fixed a bug that all password fields can not use '*' and '+' character.
2. [PPPoE]
Added the DSS over PPPoE function for PPPoE-enabled ADSL access.
Note: DSS stands for Dynamic Service Selection. If the PPPoE-enabled
ADSL access netowrk supports multiple PPPoE servers for differnet service
grade, the function can automatically connect your router to correct
PPPoE server.
3. [NAT]
Fixed a Port Redirection problem.
4. [ISDN dial-backup]
Improved the stability of ISDN dial-backup function.
5. [DDNS]
Improved DDNS function. If you have any DDNS update problem, you can use
telnet command "ddns log" to get logs.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2000
Firmware Version : v1.07c
Build Date/Time : Fri Sep 7 17:34:49.38 2001
DrayTek Corp.
Date: 2001/09/07
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k00107.all --- Lastest released firmware
(v2k00107.bin + v2k00107.web)
\Firmware\v2k00107.rst --- Lastest released firmware
(v2k00107.cfg + v2k00107.bin + v2k00107.web)
\Firmware\v2k00107.bin --- Lastest released firmware
(router program firmware only)
\Firmware\v2k00107.cfg --- The ROM file of factory default settings
excluding Lan2Lan and IP Filter
\Firmware\v2k00107.web --- The ROM file of webpages of Web Configurator
<< Tools >>>
\Tools\RtTools_2.01.exe --- This Router Tools should work with v1.07c firmware.
\Tools\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\VSetup98.exe --- Virtual TA Client 1.06 for Win98
Hint for upgrading Firmware:
1. The file v2k00107.all should be upgraded under the boot loader mode.
Please use console port (RS-232 with 115200 8n1) to force the router enter
boot loader mode.
2. If you don't care the current settings in your Vigor2000 or you want to
reset the router, you could upgrade v2k00107.rst to resotore settings
to be default values. We recommended you upgrade this file, if your
router firmware version is older than v1.03.
3. If you can't connect to console port to force router enter boot loader mode
to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator
to upgrade *.bin first and then *.web. Note that you have to wait for 10
seconds between two upgrading procedures. Finishing all upgrade, please power
off-on again.
Support Models:
Vigor2000
Release Notes:
1. [Router Tools and Virtual TA Client]
After v1.07 firmware, you should use new Router Tools 2.01 version.
2. [PPP-over-V.110]
Add PPPoV110 indication on the "Online Status" page.
3. [Always-On for PPPoE/PPTP]
Add an "Always-On" setting for PPPoE/PPTP dial-up connection.
4. [Disable PING from the Internet]
Add a checkbox under Management Setup to enable/disable PING packets from the
Internet.
5. [Call Scheduler]
Change the default settings of schedules to be 2000/01/01.
6. [RIP control for LAN]
Add a RIP control for LAN interface under "LAN TCP/IP and DHCP Setup" page. If
your local networks has many subnets want to share the router to the Internet.
Please set "RIP Protocol Control" to be "1st subnet".
7. [DNS Proxy]
Improve DNS Proxy for working with RedHat 7.1 Linux.
8. [DHCP Server]
Add a Gateway IP Address setting for DHCP server on Web Configurator.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2000
Firmware Version : v1.07
Build Date/Time : Fri Jun 22 11:49:27.86 2001
DrayTek Corp.
Date: 2001/06/22
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k00107.all --- Lastest released firmware
(v2k00106.bin + v2k00106.web)
\Firmware\v2k00107.rst --- Lastest released firmware
(v2k00106.cfg + v2k00106.bin + v2k00106.web)
\Firmware\v2k00107.bin --- Lastest released firmware
(router program firmware only)
\Firmware\v2k00107.cfg --- The ROM file of factory default settings
excluding Lan2Lan and IP Filter
\Firmware\v2k00107.web --- The ROM file of webpages of Web Configurator
<< Tools >>>
\Tools\RtTools_2.01.exe --- This Router Tools should work with v1.07 firmware.
\Tools\VSetup2k.exe --- Virtual TA Client 1.06 for Win2000
\Tools\VSetup95.exe --- Virtual TA Client 1.06 for Win95
\Tools\VSetup98.exe --- Virtual TA Client 1.06 for Win98
Hint for upgrading Firmware:
1. The file v2k00107.all should be upgraded under the boot loader mode.
Please use console port (RS-232 with 115200 8n1) to force the router enter
boot loader mode.
2. If you don't care the current settings in your Vigor2000 or you want to
reset the router, you could upgrade v2k00107.rst to resotore settings
to be default values. We recommended you upgrade this file, if your
router firmware version is older than v1.03.
3. If you can't connect to console port to force router enter boot loader mode
to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator
to upgrade *.bin first and then *.web. Note that you have to wait for 10
seconds between two upgrading procedures. Finishing all upgrade, please power
off-on again.
Release Notes:
1. [Router Tools and Virtual TA Client]
The Router Tools and Virtual TA Client have been updated, you have to uninstall
them from your computer first, then install new ones. You will get new release
in the Tools folder.
a. The system administrator password has been encrypted between router
and Smart Start Wizard.
b. Fixed a dual-CPUs problem for Virtual TA Clients.
2. [ISDN interface control]
Add a ISDN interface control option on Web Configurator to enable or disable
ISDN port. You will find the option in "ISDN Setup" of Basic Setup group.
3. [PPP-over-V.110]
Support PPP over V.110 protocol for GSM mobile users remote dial-in access.
4. [MTU setting for WAN]
Add a Telnet command "wan mtu ..." to set the MTU (Maximum Transmission Unit)
for the Ethernet WAN interface. You can use this command to configure the
MTU size for ISDN, PPPoE, PPTP and Static IP modes.
5. [SNMP Agent]
Support SNMP (Simple Network Management Protocol) for improving the capabilities
of network management. You will find SNMP Setup in the "Management Setup" of
System Management group.
6. [DDNS function]
Support DDNS (Dynamic Domain Name System) function. If you are a registered
user of www.dyndns.org (the provider of DDNS), you can give one or many domain
names for your active WAN interface using the function.
7. [Time Client and Call Scheduler]
Support NTP (Network Time Procotol) client and Call Scheduler function. The
Call Scheduler funtion provides you to schedule router's WAN connection or
LAN-to-LAN connection by your local time. The NTP client setup could be
found in "Time Setup" of System Management group. The profiles of Call Scheduler
could be found in "Call Scheduler Setup" of Advanced Setup group. Also you will
see these profiles could be assigned for Interface Access (ISDN, PPPoE and PPTP)
and LAN-to-LAN access.
8. [Online Status]
Add a System Uptime on the "Online Status" page of web configurator.
9. [DHCP Server]
If put zero in the IP Pool Counts, the dynamic IP pool will be disabled. Now you
can use Telnet command set "srv dhcp fixip" to add or delete static IP pool. This
static IP pool supports 10 IP addresses.
> srv dhcp fixip ?
% Valid subcommands are:
add clr del
Under the "srv dhcp fixip" command string, it support three subcommands: "add",
"clr" and "del".
> srv dhcp fixip add ?
% srv dhcp fixip add <IP Addr> <MAC Addr XX-XX-XX-XX-XX-XX> <Host ID>
The "add" subcommand can add a specific IP address based on host's Ethernet MAC
address. The Host ID is optional. For example, if you want to specify a IP address
192.168.1.123 to a specific computer with MAC address 00-50-7F-12-34-56, you can
try the following command to add.
> srv dhcp fixip add 192.168.1.123 00-50-7F-12-34-56 vigor
> srv dhcp fixip del ?
% srv dhcp fixip del <IP Addr>
The "del" subcommand can delete a pre-assigned IP address from the static IP pool.
For example,
> srv dhcp fixip del 192.168.1.123
the host 192.168.1.123 will be removed from the static IP pool.
> srv dhcp fixip clr
The "clr" subcommand can clear the static IP pool to default values.
10. [Verify default Settings]
A new Telnet command "sys cfg status" can check if the router is working with
default settings. If yes, you will see the following message.
> sys cfg status
Profile version: 0x2 Status: 0 (0x293ab002)
where Status: 0 (0x293ab002) means the router is default settings.
***********************************************************************************************
***********************************************************************************************
Release Notes for Vigor2000
Firmware Version : v1.06b
Build Date/Time : Thu Feb 15 16:36:46.39 2001
DrayTek Corp.
Date: 2001/02/16
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k00106.all --- Lastest released firmware
(v2k00106.bin + v2k00106.web)
\Firmware\v2k00106.rst --- Lastest released firmware
(v2k00106.cfg + v2k00106.bin + v2k00106.web)
\Firmware\v2k00106.bin --- Lastest released firmware
(router program firmware only)
\Firmware\v2k00106.cfg --- The ROM file of factory default settings
excluding Lan2Lan and IP Filter
\Firmware\v2k00106.web --- The ROM file of webpages of Web Configurator
Hint for upgrading Firmware:
1. The file v2k00106.all should be upgraded under the boot loader mode.
Please use console port (RS-232 with 115200 8n1) to force the router enter
boot loader mode.
2. If you don't care the current settings in your Vigor2000 or you want to
reset the router, you should upgrade v2k00106.rst to resotore settings
to be default values. We recommended you upgrade this file, if your
router firmware version is older than v1.03.
3. If you can't connect to console port to force router enter boot loader mode
to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator
to upgrade *.bin first and then *.web. Note that you have to wait for 10
seconds between two upgrading procedures. Finishing all upgrade, please power
off-on again.
Release Note:
1. Fixed a Typing error in ipnatdmz.sht of Web Configurator.
"Corbg." ---> "Corp."
2. ISDN dial-in improvement. Sometimes the dial-in will be failed when
the remote ISDN TA or router to use ML-PPP to dial into Vigor2000.
3. Fix a problem that Open Ports can not input 65535 port number.
4. Fix a Clear button problem under "Advanced Setup" > "IP Filter/Firewall Setup"
> "Edit Filter Set".
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2000
Firmware Version : v1.06a
Build Date/Time : Thu Jan 11 16:52:37.15 2001
DrayTek Corp.
Date: 2001/01/12
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k00106.all --- Lastest released firmware
(v2k00106.bin + v2k00106.web)
\Firmware\v2k00106.rst --- Lastest released firmware
(v2k00106.cfg + v2k00106.bin + v2k00106.web)
\Firmware\v2k00106.bin --- Lastest released firmware
(router program firmware only)
\Firmware\v2k00106.cfg --- The ROM file of factory default settings
excluding Lan2Lan and IP Filter
\Firmware\v2k00106.web --- The ROM file of webpages of Web Configurator
\Firmware\v2kfm106a.zip --- Compressed all files
<<< Router Tools & Virtual TA Client >>>
\Tools\Windows\RtSetup.exe --- Router Tools for all Windwos Platforms
\Tools\Windows\VSetup2k.exe --- VTA client for Windows 2000
\Tools\Windows\VSetup95.exe --- VTA client for Windows 95
\Tools\Windows\VSetup98.exe --- VTA client for Windows 98
\Tools\Mac OS\Vigor2000 Tools Installer.hqx
--- Vigor2000 Tools for Mac OS
Hint for upgrading Firmware:
1. The file v2k00106.all should be upgraded under the boot loader mode.
Please use console port (RS-232 with 115200 8n1) to force the router enter
boot loader mode.
2. If you don't care the current settings in your Vigor2000 or you want to
reset the router, you should upgrade v2k00106.rst to resotore settings
to be default values. We recommended you upgrade this file, if your
router firmware version is older than v1.03.
3. If you can't connect to console port to force router enter boot loader mode
to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator
to upgrade *.bin first and then *.web. Note that you have to wait for 10
seconds between two upgrading procedures. Finishing all upgrade, please power
off-on again.
Release Note:
1. Improve DMZ host function for Mac OS 9.
2. Add Open Ports function which allow users to open a port range
for specific network applications.
3. Improve NAT engine for FTP protocol pass-thru.
4. Fix a LAN-to-LAN and ISP access via ISDN simultaneouly problem which
when a LAN-to-LAN connection is up the ISP access will be failed.
5. Improve Web Configurator for more user-friendly with JavaScripts.
6. Improve Web Configurator for IE 5.5 and Netscape 6.0 browser.
7. IPSec ESP tunnel mode pass-thru support.
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2000
Firmware Version : v1.06
Build Date/Time : Thu Nov 2 16:10:53.64 2000
DrayTek Corp.
Date: 2000/11/02
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k00106.all --- Lastest released firmware
(v2k00106.bin + v2k00106.web)
\Firmware\v2k00106.rst --- Lastest released firmware
(v2k00106.cfg + v2k00106.bin + v2k00106.web)
\Firmware\v2k00106.bin --- Lastest released firmware
(router program firmware only)
\Firmware\v2k00106.cfg --- The ROM file of factory default settings
excluding Lan2Lan and IP Filter
\Firmware\v2k00106.web --- The ROM file of webpages of Web Configurator
\Firmware\v2kfm106.zip --- Compressed all files
<<< Router Tools & Virtual TA Client >>>
\Tools\Windows\RtSetup.exe --- Router Tools for all Windwos Platforms
\Tools\Windows\VSetup2k.exe --- VTA client for Windows 2000
\Tools\Windows\VSetup95.exe --- VTA client for Windows 95
\Tools\Windows\VSetup98.exe --- VTA client for Windows 98
\Tools\Mac OS\Vigor2000 Tools Installer.hqx
--- Vigor2000 Tools for Mac OS
Hint for upgrading Firmware:
1. The file v2k00106.all should be upgraded under the boot loader mode.
Please use console port (RS-232 with 115200 8n1) to force the router enter
boot loader mode.
2. If you don't care the current settings in your Vigor2000 or you want to
reset the router, you should upgrade v2k00106.rst to resotore settings
to be default values. We recommended you upgrade this file, if your
router firmware version is older than v1.03.
3. If you can't connect to console port to force router enter boot loader mode
to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator
to upgrade *.bin first and then *.web. Note that you have to wait for 10
seconds between two upgrading procedures. Finishing all upgrade, please power
off-on again.
Release Note:
1. PPTP client for few specific PPTP-enabled ADSL modem
To click "Quick Setup" > "Internet Access Setup" > "PPTP" configures
PPTP and also can configure the ISDN dial backup settings.
Note: Before you enable the PPTP client, you should use 2nd IP address to connect
to the ADSL modem. Please click "Basic Setup" > "Ethernet TCP/IP and DHCP
Setup" to enable the 2nd IP address and assign the IP address and subnet mask.
2. Netmeeting support
The Netmeeting support is just a beta release. Based on the current release, you
just can make a Netmeeting call directly using peer IP address. If you want to peer
to call into your local Netmeeting software, please add two port redirection entries
in the "Advanced Setup" > "NAT Setup" > "Configure Port Redirection Table". These
additional ports is TCP/1720 and TCP/1503. However, the ILS server support should
be released in the next version.
3. PPTP Tunnel Passthru
This version supports any of PPTP clients could create a tunnel through the router to
establish a secure channel with outside PPTP server.
4. PPPoE Enhancement
This version has done some significant performance improvement for T-DSL services
in Germany. If you are a T-DSL user, please use the version.
5. Tools for Windows Platform
Now, the Windows utility has been separate to two independent installers,
one is named "Router Tools" including "Firmware Upgrade Utility" and "Smart Start
Wizard", the other is named "Virtual TA" client driver which has been supported for
Win95 OSR2.1, Win98 and Win2000. The Router Tools can support whole Windows platforms.
6. LAN-to-LAN Profile bug
Fixed a bug which the LAN-to-LAN profile settings will be clear to be default
value after upgrade new firmware.
7. Call Control Parameters
Please click "Advanced Setup" > "Call Control and PPP/MP Setup", you will see the
following two parameters: Dial Retry and Dial Delay Interval. These are globally
settings for all dial-out mechanism, such as ISDN dialup, PPPoE or PPTP for ADSL
access. The Dial Retry means the router will dial the preset times per outgoing
packet. The Dial Delay Interval means the time interval between two re-dials.
8. Remote Activation Function
Please click "Advanced Setup" > "Call Control and PPP/MP Setup", you will see the
"Remote Activation" field. You should specify the caller phone number here. Once the
router receives a call from the specified phone or ISDN line number, it is will
drop the incoming call immediatelly and then dial to the ISP for the Internet access.
If you are a fixed IP user, the router will be wake up remotely, then you could
access to your local network resource very easy.
Note: Before you enable the function, you should set a ISP access profile following
the links "Quick Setup" > "Internet Access Setup" > "Dialling to Single ISP".
9. Remote Management
Add a "Allowing management from the Internet" checkbox on the Management Setup page
of Web Configurator. By default, the checkbox is unchecked. It means the router
can NOT configure from the Internet.
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2000
Firmware Version : v1.05a
Build Date/Time : Tue Aug 8 15:8:36.46 2000
DrayTek Corp.
Date: 2000/08/08
***********************************************************************************************
Files Description:
<<< Firmware >>>
\Firmware\v2k00105.all --- Lastest released firmware
(v2k00105.bin + v2k00105.web)
\Firmware\v2k00105.rst --- Lastest released firmware
(v2k00105.cfg + v2k00105.bin + v2k00105.web)
\Firmware\v2k00105.bin --- Lastest released firmware
(router program firmware only)
\Firmware\v2k00105.cfg --- The ROM file of factory default settings
excluding Lan2Lan and IP Filter
\Firmware\v2k00105.web --- The ROM file of webpages of Web Configurator
\Firmware\v2kfm105.zip --- compressed file of this folder
<<< Vigor2000 Tools >>>
\Tools\VSetup.exe --- Vigor2000 Tools for Windwos NT
\Tools\VSetup2k.exe --- Vigor2000 Tools for Windows 2000
\Tools\VSetup95.exe --- Vigor2000 Tools for Windows 95
\Tools\VSetup98.exe --- Vigor2000 Tools for Windows 98
\Tools\Vigor2000 Tools Installer.hqx
--- Vigor2000 Tools for Mac OS
\Tools\v2ktools.zip --- compressed file of VSetup.exe, VSetup2k.exe
, VSetup95.exe and VSetup98.exe.
Hint for upgrading Firmware:
1. The file v2k00105.all should be uploaded under the boot loader mode.
Please refer to "fmup.doc" for details of how to enter the boot loader mode
as well as how to upload.
2. If you don't care the current settings in your Vigor2000, you also can
upgrade v2k00105.rst to resotore settings to be default value. We recommended
you upgrade this file, if your Vigor2000's firmware version is older than
v1.03.
3. If you can't connect to console port to force router enter boot loader mode
to upgrade *.all or *.rst file, please enable TFTP server via Web Configurator
to download *.bin first and then *.web. Note that you have to wait about 10
seconds between two upgeading procedures. Finishing all upgrade, please power
off-on again.
New Features:
1. PPPoE with ISDN dial backup
To click "Quick Setup" > "Internet Access Setup" > "PPPoE" configures
PPPoE and also can configure the ISDN dial backup settings.
2. LAN-to-LAN connectivity (local LAN to remote LAN communications)
To click "Advanced Setup" > "LAN-to-LAN Dialer Profile Setup" configures
LAN-to-LAN dialer profiles for LAN-to-LAN communications. Current beta version
just supports the 1st IP network which is for NAT usage to route to remote
network.
3. Management Port Change and Access Control
To click "System Management" > "Management Setup" configures the HTTP and Telnet
port number, also access control for management host. The Access Control means
system administrator can limit the management host from specific network or host.
That is more secure for system administrator.
4. Web-based IP Filter/Firewall Configuration
To click "Advanced Setup" > "IP Filter/Firewall Setup" configures IP filter rules.
The basic Firewall concept is described as below.
Inside Network Outside Network
+----------+
------------------------+ Firewall +-----------------------------------
+----------+
1st IP network ISDN dial-out/dial-in
2nd IP network or PPPoE
or LAN-to-LAN connection
or IDSL (U-interface)
Current beta release, Vigor2000 supports these filter rules to defend heakers
attack form outside network, and also limit some access rights for inside network.
[Updated Features, 2000/07/15]
1. Add Enable/Disable radio for 2nd IP configurations, please click
"Basic Setup" > "Ethernet TCP/IP and DHCP Setup". Also, once the
1st IP or 2nd IP configurations has been changed, the start IP
address of DHCP server will follow the change.
2. Add "Exchange RIP Packets" item on each LAN-to-LAN dialer profile.
If you want to use 1st IP subnet to make a outgoing call, and
select "2nd Subnet" for exchanging RIP packets, the 1st IP subnet
will be a non-routable subnet behind of NAT engine. Another
application, you can use 1st IP subnet to make a remote network
connection with IP routing, when you select "1st Subnet" to exchange
RIP packets.
3. Add Telnet-based simplified "Call Log" for troubleshooting. You can
use "log -c" command to show all call log.
[Updated Features, 2000/08/08]
1. Improve a RIP stable problem somehow RIP task will crash all
the system.
2. Increase IP counts for DHCP server to 253 hosts, also the
default Start IP Address of DHCP server has been changed to be
192.168.1.10.
3. Remove "Static Route Setup" on Advanced Setup group. The reason we merge
the static route function in the LAN-to-LAN Dialer Profile Setup. Please
check each profile includes a TCP/IP Network Settings subgroup. The Remote
Gateway IP means remote node's gateway IP address, Remote Network IP means
remote node network ID (ex. 192.168.1.0 is the network IP of 192.168.1.0
with netwrok mask 255.255.255.0(24)) and Remote Neetwork Mask is remote
node's network mask.
Once this profile has been matched by any triggered packets from local
network, Vigor2000 will select the matched profile to dial to remote node
and also will add a static route on routing table.
4. If you want to create another ISP access using LAN-to-LAN Dialer Profile
Setup. Please force Exchange RIP Packets to "2nd subnet". It means all of
IP addresses/ports on the 1st subnet will be translated by NAT engine.
5. If you want to reject some packets to trigger Vigor2000 dialing, but allow
these packets can be forwarding to outside network during online. You can
set filter rules on Call Filter. Please click "IP Filter/Firewall Setup"
on Advanced Setup group and click "Set 1 Default Call Filter" > "2" to add
a call filter.
6. When you updating LAN IP address the Start IP Address of DHCP server will
be followed.
7. Fixed some bugs on "IP Filter/Firewall Setup". Now any kind of illegal
configurations will not display CGI error.
8. Add a Vigor2000 Tools for Windows NT platform named VSetup.exe. In this
tool does not include Virtual TA client driver, just Smart Start Wizard
and Firmware Upgrade Utility.
9. Fixed a configuration backup function using Firmware Upgrade Utility.
How to backup Vigor2000's current running configuration:
(1) Open Firmware Upgrade Utility and click Option menu to select
Download Configuration on Vigor2000 Tools group.
(2) Type router's IP on Host box.
(3) Give a file name on Save File box or click Brose to select a
file to save. The file name should be formated as v2kxxxxx.cfg
where xxxxx should be number characters.
(4) Enable TFTP server using Web Configrator.
(5) Push Download button to get configurations rom file back.
>> Bugs report to support@draytek.com.tw or ccwen@draytek.com.tw
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2000 v1.04a Mon May 22 15:28:12.8 2000
DrayTek Corp.
Date: 2000/05/22
***********************************************************************************************
Files Description:
\Firmware\v2k00104.all --- Lastest released firmware
(v2k00104.bin + v2k00104.web)
\Firmware\v2k00104.rst --- Lastest released firmware
(v2k00104.cfg + v2k00104.bin + v2k00104.web)
\Firmware\v2k00104.bin --- Lastest released firmware
(router program firmware only)
\Firmware\v2k00104.cfg --- The rom file of factory default settings
\Firmware\v2k00104.web --- The rom file of webpages of Web Configurator
\Tools\VSetup2k.exe --- Vigor2000 Tools for Windows2000
\Tools\VSetup95.exe --- Vigor2000 Tools for Windows95
\Tools\VSetup98.exe --- Vigor2000 Tools for Windows98
Note: After installing Vigor200 Tools, you can read a readme file
to get more details.
Hint for upgrading Firmware:
1. The file v2k00104.all should be uploaded under the boot loader mode.
Please refer to "fmup.doc" for details of how to enter the boot loader mode
as well as how to upload.
2. If you don't care the current settings in your Vigor2000, you also can
upgrade v2k00104.rst to resotore settings to be default value. We recommended
you upgrade this file, if your Vigor2000's firmware version is older than
v1.03.
Patches for v1.04:
1. Tuning PPPoE client to be compatible with T-Online T-DSL services.
2. Fixed an IDSL problem in v1.04.
3. Allow "admin" be an username for logining Vigor2000 using some web browser.
4. Fixed some webpages minor bugs.
5. Timbuktu can work behind our NAT, but you should add a UDP port 407
for incoming from Internet.
6. PING fragmentation problem has been fixed.
The problem is when multiple PCs ping to the same host with fragmented ICMPs
will fail.
7. PPPoE can disconnect more quickly when you use manaul drop on the web user
interface.
8. Fixed a trace route bug using Linux's "traceroute" utility.
>>> Below is the same as v1.04 release notes ---------------------------------------
New Features:
1. PPPoE client built-in for DSL sharing
Vigor2000 can connect to external DSL modem running as a NAT
router to share DSL line and single ISP account for multiple
users to get on Internet simultaneously.
2. IP routing with broadband gateway or leased line gateway router
Vigor2000 can bind two IP addresses on the single Ethernet interface.
One private IP address connects to a private subnet to communicate
with other private hosts and another public IP address connects to
a public subnet and gateway router to Internet. Beside the IP sharing
and IP routing works together, Vigor2000 also can dial backup using
ISDN line.
3. Router configurations backup
New Firmware Upgrade Utility can get back current router configuration
via TFTP protocol and save to be a file.
4. New layout for web configurator
The simple, easy-to-look and easy-to-use web-based user interface.
5. New Windows platform utility named Vigor2000 Tools
This tools include Frimware Upgrade Utility, Virtual TA client and
Smart Start Wizard. These utilities can support Windows95/98/2000.
Improvements:
[New Feature]
1. Virtual TA change to use username/password authetication. If you
want to enable Virtual TA function, please install Vigor2000 Tools
first.
2. Just use password field to login Web configurator, please leave
the username field to be blank.
[Known Bug]
1. The fragemented ICMP will be dropped through NAT engine.
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2000 v1.04 05051300
DrayTek Corp.
Date: 2000/05/05
***********************************************************************************************
Files Description:
\Firmware\v2k00104.all --- Lastest released firmware
(v2k00104.bin + v2k00104.web)
\Firmware\v2k00104.rst --- Lastest released firmware
(v2k00104.cfg + v2k00104.bin + v2k00104.web)
\Firmware\v2k00104.bin --- Lastest released firmware
(router program firmware only)
\Firmware\v2k00104.cfg --- The rom file of factory default settings
\Firmware\v2k00104.web --- The rom file of webpages of Web Configurator
\Tools\VSetup2k.exe --- Vigor2000 Tools for Windows2000
\Tools\VSetup95.exe --- Vigor2000 Tools for Windows95
\Tools\VSetup98.exe --- Vigor2000 Tools for Windows98
Note: After installing Vigor200 Tools, you can read a readme file
to get more details.
Hint for upgrading Firmware:
1. The file v2k00104.all should be uploaded under the boot loader mode.
Please refer to "fmup.doc" for details of how to enter the boot loader mode
as well as how to upload.
2. If you don't care the current settings in your Vigor2000, you also can
upgrade v2k00104.rst to resotore settings to be default value. We recommended
you upgrade this file, if your Vigor2000's firmware version is older than
v1.03.
New Features:
1. PPPoE client built-in for DSL sharing
Vigor2000 can connect to external DSL modem running as a NAT
router to share DSL line and single ISP account for multiple
users to get on Internet simultaneously.
2. IP routing with broadband gateway or leased line gateway router
Vigor2000 can bind two IP addresses on the single Ethernet interface.
One private IP address connects to a private subnet to communicate
with other private hosts and another public IP address connects to
a public subnet and gateway router to Internet. Beside the IP sharing
and IP routing works together, Vigor2000 also can dial backup using
ISDN line.
3. Router configurations backup
New Firmware Upgrade Utility can get back current router configuration
via TFTP protocol and save to be a file.
4. New layout for web configurator
The simple, easy-to-look and easy-to-use web-based user interface.
5. New Windows platform utility named Vigor2000 Tools
This tools include Frimware Upgrade Utility, Virtual TA client and
Smart Start Wizard. These utilities can support Windows95/98/2000.
Improvements:
[New Feature]
1. Virtual TA change to use username/password authetication. If you
want to enable Virtual TA function, please install Vigor2000 Tools
first.
2. Just use password field to login Web configurator, please leave
the username field to be blank.
[Known Bug]
1. The fragemented ICMP will be dropped through NAT engine.
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2000 ver 1.03a
DrayTek Corp.
Date: 2000/03/13
***********************************************************************************************
Files Description:
\FW\v2k00103.bin --- Lastest released firmware
(router program firmware only)
\FW\v2k00103.all --- Lastest released firmware
(v2k00101.bin + v2k00101.web)
\FW\v2k00103.rst --- Lastest released firmware
(v2k00101.cfg + v2k00101.bin + v2k00101.web)
\FW\v2k00103.cfg --- The rom file of factory default settings
\FW\v2k00103.web --- The rom file of webpages of DrayWeb Configurator
\Utility\Windows\FUSetup.zip --- DrayTek Firmware Upgrade Utility
\Utility\Windows\SmartStart.zip --- Smart Start Wizard for quick installation
\Utility\MacOS\utility.hqx --- Smart Start Wizard and Firmware Upgrade
Utility for Mac OS
\VTA\VSetup95.exe --- Virtual TA client driver for Windows95
\VTA\VSetup98.exe --- Virtual TA client driver for Windows98
Hint for upgrading Firmware:
1. The file v2k00103.all should be uploaded under the boot loader mode.
Please refer to "fmup.doc" for details of how to enter the boot loader mode
as well as how to upload.
Improvements:
[Web Configurator]
1. Add Ethernet MAC address on "LAN Diagnostic". The format is:
dd dd dd dd dd dd-ss ss ss ss ss ss-tt tt
where the HEX format
"dd dd dd dd dd dd" is destination MAC address,
"ss ss ss ss ss ss" is source MAC address,
"tt tt" is upper protocol type.
2. Add a well-known ports list for NAT port redirection settings. Please click
"IP Routing" >> "Private IP Application (NAT)" >>
"Well-Known or Specific Application Ports List" to get more detail.
3. Add "Leased 64kbps" and "Leased 128kbps" for configuring to be client-side
IDSL access router. You can click "PPP/MP Dial-Out" >> "Link type" to select
"Leased 64Kbps" or "Leased 128Kbps" for working with IDSL access server.
4. (bugfix) The authetication of web configurator is fialed when system
administrator changed system username/password via console port.
[NAT]
1. Support pcAnyWhere 9.0 application under NAT environment. You can start
pcAnyWhere software on a private local host. Once Vigor2000 has been connected
to ISP. It will get a public IP for the ISDN WAN link on the Internet. At the
moment, the network administrator can use pcAnyWhere remotely control this
private local host from the Internet via pcAnyWhere protocol.
2. (bugfix) When the Vigor2000's WAN link is connected to ISP. The local private
host browse WAN IP using web browser will crash web server built in Vigor2000.
Now, we reject these kind of packets to access web configurator using WAN IP
by any of private local hosts, therefore, these local private host should use
the local private IP of Vigor2000 to access its web configurator and Telnet
server.
[Telnet]
1. Add raw hex format for CAPI messages for ISDN WAN tracelog commands "log -i" and
"log -w".
[TCP/IP]
1. (bugfix) The system will be crashed when the Unix-clone (ex. Linux, Sun Solaries)
send special QUERY requests through Vigor2000's DNS proxy.
[ISDN]
1. The function of client-side IDSL access router is supported. Now, we provide
64Kbps/128Kbps transmission speed. Please refer to above section [Web Configurator]
for getting more detailed configurations.
[PPP/MP]
1. Improve the data transmission throughput for MP (Multiple Link PPP) connection.
[Virtual TA client drivers]
1. Update Virtual TA client driver for Windows95/98 platform. Before you install
this software, please uninstall last version first.
[Smart Start Wizard & DrayTek Firmware Upgrade Utility]
1. Beta release for Mac OS users. You can download it under the following folder
~\1.03\Utility\MacOS\utility.hqx of ftp.draytek.com.
[HDLC Driver]
1. Improve HDLC drivers for stability and efficiency.
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2000 ver 1.03
DrayTek Corp.
Date: 2000/02/21
*******************************************************************************
Files Description:
\FW\v2k00103.zip --- firmware Ver. 1.03 named v2k00103.all
\Utility\Windows\FUSetup.zip --- DrayTek Firmware Upgrade Utility
\Utility\Windows\SmartStart.zip --- Smart Start Wizard for quick installation
\Utility\MacOS\utility.hqx --- Smart Start Wizard and Firmware Upgrade
Utility for Mac OS
\VTA\VSetup95.exe --- Virtual TA client driver for Windows95
\VTA\VSetup98.exe --- Virtual TA client driver for Windows98
Hint for upgrading Firmware:
1. The file v2k00103.all should be uploaded under the boot loader mode.
Please refer to "fmup.doc" for details of how to enter the boot loader mode
as well as how to upload.
Improvements:
[Web Configurator]
1. Add Ethernet MAC address on "LAN Diagnostic". The format is:
dd dd dd dd dd dd-ss ss ss ss ss ss-tt tt
where the HEX format
"dd dd dd dd dd dd" is destination MAC address,
"ss ss ss ss ss ss" is source MAC address,
"tt tt" is upper protocol type.
2. Add a well-known ports list for NAT port redirection settings. Please click
"IP Routing" >> "Private IP Application (NAT)" >>
"Well-Known or Specific Application Ports List" to get more detail.
3. Add "Leased 64kbps" and "Leased 128kbps" for configuring to be client-side
IDSL access router. You can click "PPP/MP Dial-Out" >> "Link type" to select
"Leased 64Kbps" or "Leased 128Kbps" for working with IDSL access server.
4. (bugfix) The authetication of web configurator is fialed when system
administrator changed system username/password via console port.
[NAT]
1. Support pcAnyWhere 9.0 application under NAT environment. You can start
pcAnyWhere software on a private local host. Once Vigor2000 has been connected
to ISP. It will get a public IP for the ISDN WAN link on the Internet. At the
moment, the network administrator can use pcAnyWhere remotely control this
private local host from the Internet via pcAnyWhere protocol.
2. (bugfix) When the Vigor2000's WAN link is connected to ISP. The local private
host browse WAN IP using web browser will crash web server built in Vigor2000.
Now, we reject these kind of packets to access web configurator using WAN IP
by any of private local hosts, therefore, these local private host should use
the local private IP of Vigor2000 to access its web configurator and Telnet
server.
[Telnet]
1. Add raw hex format for CAPI messages for ISDN WAN tracelog commands "log -i" and
"log -w".
[TCP/IP]
1. (bugfix) The system will be crashed when the Unix-clone (ex. Linux, Sun Solaries)
send special QUERY requests through Vigor2000's DNS proxy.
[ISDN]
1. The function of client-side IDSL access router is supported. Now, we provide
64Kbps/128Kbps transmission speed. Please refer to above section [Web Configurator]
for getting more detailed configurations.
[PPP/MP]
1. Improve the data transmission throughput for MP (Multiple Link PPP) connection.
[Virtual TA client drivers]
1. Update Virtual TA client driver for Windows95/98 platform. Before you install
this software, please uninstall last version first.
[Smart Start Wizard & DrayTek Firmware Upgrade Utility]
1. Beta release for Mac OS users. You can download it under the following folder
~\1.03\Utility\MacOS\utility.hqx of ftp.draytek.com.
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2000 ver 1.02
DrayTek Corp.
Date: 2000/01/25
***********************************************************************************************
Files Description:
\FW\v2k00102.all --- Vigor2000 firmware ver. 1.02
\FW\v2k00102.zip --- pkzip compressed file for v2k00102.all
\Utility\FUSetup.exe --- DrayTek Firmware Upgrade Utility
\Utility\SmartStart.exe --- Smart Start Wizard for quick installation
\VirtualTA\VSetup95.exe --- Virtual TA client driver for Windows95
\VirtualTA\VSetup98.exe --- Virtual TA client driver for Windows98
Hint for upgrading Firmware:
1. The file v2k00102.all should be uploaded under the boot loader mode.
Please refer to "fmup.doc" for details of how to enter the boot loader mode
as well as how to upload.
Improvements:
[DrayWeb]
1. Add a menu bar "IP Routing" on "Advanced Setup" for setting NAT port assignment
we called Public Server Functions.
2. Modify "ISP Info" menu to support Dual ISPs Function.
3. Due to the system memory limitation, we remove three appication pages linked
from home page.
4. Add "Own Number" settings field for ISDN configurations.
[NAT]
1. Public Server Function: The function can use NAT port translation method to
export your private servers to world-wide Internet. You can click "Advanced
Setup" >> "IP Routing" >> "NAT" to configure a port assignment table. Before
you export private server to Internet, you have to make sure it does work
properly in your private local network.
2. Callback Client Function:
If your ISP or remote network provides callback features, you can
enable the function on "Advanced Setup" >> "ISP Info" >> Single or Dual ISP
>> click "Require ISP callback".
3. Fixed a long password problem with FTP application.
[TCP/IP]
1. default and static routes can save to Flash ROM. Now, we provide ten
static route entries in system profile.
--- Add a static route using TUI command:
draytek > ip route add <dest addr> <subnet mask> <gatew addr> <iface> static
where
dest addr : destination host IP address
subnet mask : subnet mask
gatew : gateway IP address
iface : interface number, 0 --- Ethernet, 1 --- ISDN
--- Delete a default/static route using TUI command:
draytek > ip route del <dest addr> <subnet mask>
--- Add a default route using TUI command:
draytek > ip route add <dest addr> <subnet mask> <gatew addr> <iface> default
2. Add traceroute support even using NAT network environment.
[ISDN]
1. Fix an ISDN dialup problem that, occasionally, Vigor2000 has been
running for few days.
[Smart Start Wizard]
1. Modify every dialog boxes to be more comercialization.
[Virtual TA client driver]
1. Update Virtual TA client driver for Windows95/98 platform. Before you install
this software, please uninstall last version first.
***********************************************************************************************
***********************************************************************************************
Release Note for Vigor2000 ver 1.01
DrayTek Corp.
Date: 1999/12/03
***********************************************************************************************
Hint for upgrading Firmware:
1. For this revision you have to upload either "V2k00101.all" or
"V2k00101.rst" depending on your current firmware version. Both of
the files should be uploaded under the boot loader mode. Please refer
to "fmup.doc" for details of how to enter the boot loader mode
as well as which file to upload.
2. For later revisions, if the DrayWeb is not modified, you may use
the easizer run-time firmware upgrade function in the DrayWeb's
"System Utilities" >> "F/W Upgrade" to upload the binary program
code that is "V2k00101.bin" for Version 1.01.
Improvements:
[DrayWeb]
1. Implement an ECMAscript to recognize which browser you use. Because
DrayWeb has some HTML compatibility with differnet browsers.
2. Add a menu bar on "Advanced Setup" for setting dial-in users
accounts.
3. Add some configuration fields of secure callback functions for
specific remote dial-in users.
4. Fixed a long URL with authentication prefix bug.
[Remote Dial-In]
1. Implemented callback functions for Windows 95/98/NT users using tra-
ditional ISDN TA devices. In this features, we also support callback
budget control and CLID authentication. Before you verify
the CLID authentication feature, you have to make sure your testing
environment can sending "Calling party number" by ISDN switch.
2. Fixed a bug in remote dial-in access feature. The original bug
is when we make a call to Vigor2000 about 200 times, it will
not accept incoming call.
[Virtual TA]
1. Tuning Virtual TA server for more stable and robust, now the FAX/
File transfer is OK, but minitel application doesn't work fine. We
are still fixing the bug.
2. Update Virtual TA client draiver for Windows95/98 platform.
[TCP/IP]
1. Fixed a bug in receving PING packets from Linux box.
2. Fixed a IP brocast problem during remote dial-in access.
[Software Utility]
1. Release a Smart Start Utility for first setup.
*******************************************************************************
Testing Note:
1. You can follow the steps below to create an access server using
Vigor2000:
--------------+-------------------------------- Company Network
|
|
+-----------+
| |
| Vigor2000 |
| |
+--+--------+
|
|ISDN for dial-in only
Step1: set IP and netmask (public IP) to fit your company network using
console port.
Step2: Enable remote dial-in, please follows "Quick Setup" >> "Remote
Dial-In" to configure them. Here you HAVE to assign company
IPs (public IP) for dial-in users to user.
Step3: Following the last step, to create a dial-in access account
for remote Vigor2000 dialup.
Step4: Turn off NAT server, using TUI command as following.
draytek > srv nat off
Step5: Reboot router using the following TUI command.
draytek > sys reboot
... Now you will lost Telnet connection ...
Step6: After power-on to add a static/default route for accessing
world-wide Internet via TUI command as below.
draytek > ip route add 0.0.0.0 0.0.0.0 <gateway IP> 0 default
where
<gateway IP> should use your company's default gateway IP.
Note: Current version the static route will be lost when router
power down.
Step7: Now you can use another Vigor2000 to dial into the access
server made by Vigor2000 too.
2. Make sure your Virtual TA client is up-to-date VSetup95.EXE and
VSetup98.EXE.
3. Start.DOC can provide you to get more understand what kind of
applications Vigor2000 can do.
*******************************************************************************
Files Decription with this CDROM for Vigor2000 isdnRouter
DrayTek Corp.
Ver. 1.01
Nov. 30
*******************************************************************************
*** Contents ***
README.TXT --- This readme file
\FW\v2k00101.bin --- Lastest released firmware
(router program firmware only)
\FW\v2k00101.all --- Lastest released firmware (v2k00101.bin + v2k00101.web)
\FW\v2k00101.rst --- Lastest released firmware
(v2k00101.cfg + v2k00101.bin + v2k00101.web)
\FW\v2k00101.cfg --- The rom file of factory default settings
\FW\v2k00101.web --- The rom file of webpages of DrayWeb Configurator
\DOCS\Start.doc --- Getting Started document
\DOCS\fmup.doc --- Firmware Upgrade manual
\DOCS\tui.doc --- Telnet comnands reference manual
\DOCS\iMac.doc --- Installation with iMac HOW-TO
\DOCS\Vtac.doc --- Virtual TA client driver installation guide
\DOCS\ipf.doc --- IP filter user's guide
\DOCS\cover.doc --- Cover page
\DOCS\quick.rtf --- Quick installation guide
\DOCS\software.rtf --- Software installation guide
\UTILITY\FUSetup.exe --- DrayTek Firmware Upgrade Utility
\UTILITY\SmartStart.exe --- Smart Start Wizard for quick installation
\VTA\VSetup95.exe --- Virtual TA client draiver for Windows95
\VTA\VSetup98.exe --- Virtual TA client driver for Windows98
***********************************************************************************************